Skip to main content
Press enter to search

Contact

Contact Form
(S)TH14

Immersion Pumps (S)TH14

Immersion Pumps
series TH and FH use closed impellers in order to minimize power consumption and to optimize hydraulic pump efficiencies.
In addition, the TH series offers high pressures at short immersion depths.
Inline pumps of the series FH can be used as boosting pumps if provided with positive inlet pressure. This inlet pressure can be provided by the central coolant supply or a feed pump. In such a setup, pumps of the series FH can raise the incoming pressure by up to 26 bar.

Extended length is possible. See medium pressure pumps features within the technical information section.



Closed impellers

Technical drawing


(S)TH14

Immersion Pumps - (S)TH14



STH1402...1417
*) Dimension for (S)TH1402...1403**) Dimension for (S)TH1408...1411***) Dimension for (S)TH1412...1416****) Dimension for (S)TH1417




TH1402...1417


Pump characteristic


yaxis (S)TH14
xaxis

Immersion Pumps - (S)TH14

yaxis (S)TH14
xaxis

Applications

Types of fluidIndustrial water
coolants
cooling/cutting oils
Kinematic viscosity...25 mm²/s (25 cSt)
Pumping temperature0...80° C

Construction

 

 

 

 

 

Pump bodycast iron
Covercast iron
ImpellersCrNi-steel
ShaftCrNi-steel
DiffusersCrNi-steel
Mechanical sealSiC
O-ringsViton
Optional:
Pump bodyCrNi-steel
CoverCrNi-steel
Pole-changing motor4 - 2 poles
Noise level 63 dBA ((S)TH1402...(S)TH1403A)
71 dBA ((S)TH1404...(S)TH1407A)
74 dBA ((S)TH1408...(S)TH1416A)
78 dBA ((S)TH1417...(S)TH1417A)


Type Vol. del.
at manom.
del. head
Height Depth
of im-
mersion
Weight
  Power Voltage
3 ~
Fre-
quen-
cy
Current Speed
l/min /m H mm h mm kg kW V Hz A 1/min
(S)TH1402A180    cad 250/21 459 182 37.0 1.7 220-240 50
6.24
2890
  380-415 50
3.60
2890
(S)TH1403A280    cad 250/38 492 278 43.0 2.6 220-240 50
9.30
2880
  380-415 50
5.35
2880
(S)TH1404A280    cad 250/48 531 278 55.0 3.3 220-240 50
11.6
2930
  380-415 50
6.7
2930
(S)TH1405A380    cad 250/60 531 374 57.0 4.0 220-240 50
14.50
2920
  380-415 50
8.35
2920
(S)TH1406A380    cad 250/74 561 374 64.0 5.0 220-240 50
17.3
2920
  380-415 50
10.0
2920
(S)TH1407A470    cad 250/85 561 470 66.0 5.5 220-240 50
18.9
2915
  380-415 50
10.9
2915
(S)TH1408A470    cad 250/98 640 470 98.0 7.5 380-415 50
14.3
2950
(S)TH1409A570    cad 250/110   566 102.0      
 
 
(S)TH1410A570    cad 250/120 640 566 110.0 9.0 380-415 50
16.7
2955
(S)TH1411A660    cad 250/134   662 115.0      
 
 
(S)TH1412A660    cad 250/144 647 662 131.0 11.0 380-415 50
20.1
2960
(S)TH1413A760    cad 250/159   758 135.0      
 
 
(S)TH1414A760    cad 250/170 647 758 139.0 13.0 380-415 50
24.2
2960
(S)TH1415A900    cad 250/180   902 143.0      
 
 
(S)TH1416A900    cad 250/190     145.0      
 
 
(S)TH1417A900    cad 250/200 952 902 161.0 15.0 400 50
27
2960

Pumps

Quickfinder